| SKU | Connection |
|---|---|
| 60010CP | 15mm |
| 60011CP | 22mm |
| No downloads available. |
| No videos available. |
Temperature Adjustment Range: 30°C to 50°C
Temperature Stability: ±2°C
Maximum Inlet Temperature: 85°C
Maximum Working Pressure: 10 Bar Static
Minimum Working Pressure: 0.2 Bar Dynamic
Maximum Pressure Inlet differential: 5:1
Maximum Temperature Differential Between Hot Inlet & Mixed Outlet to Achieve Failsafe: 10°C
The Intatec range of 15 and 22mm thermostatic mixing valves are designed primarily for single outlet use.
Unlike T-pattern valves the hot and the mixed water ports are perpendicular, which reduces the need for pipework modifications and helps to save a significant amount of installation time – especially in retro fit application.
The element that controls the temperature of the mixed water discharging from the valve works proportionally on both hot and cold water supplies in order to maintain the temperature of the mixed water discharged.