Inta Zero Anti-Freeze Valve Professional Installer Pack

SKUConnectionKv-value
AFCOMPACK28mm64m³/h
AFCOMPACK3535mm70m³/h
AFCOMPACK11" Male55m³/h
AFCOMPACK1141 1/4" Male70m³/h
AFCOMPACKSW1" Male x 1" Female Swivel33m³/h
AFCOMPACKSW351 1/4" Male x 1 1/4" Female Swivel52m³/h
No downloads available.

Anti-Freeze Valve

  • Max Inlet Pressure (Static): 10 Bar
  • Working Temperature Range: 0 to 80°C
  • Ambient Temperature Range: -30 to 60°C
  • Opening Temperature: 3°C
  • Closing Temperature: 4°C
  • Sensitivity: ±1°C
  • Medium: Water
  • Max Discharge Flow Rate @ 3 Bar: 1.5 L/H

Insulation

  • Wall thickness: 19mm +0 / -3mm
  • Material: treated closed cell polyethylene
  • Temperature range: -45°C to 105°C
  • Thermal conductivity: λ = 0.034 W/mk at 0°C
  • Water vapour diffusion resistance: μ ≥ 39,300

The patented Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate.

Building regulations Part L states that all external fittings on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.

The Inta Zero Anti-Freeze valves have been Independently tested using a controlled Ambient Temperature between -1°C to 1°C and starting water temperature 10°C to demonstrate the possibility of insulating the Inta Zero Valve without affecting the performance:

Without Insulation
Water Discharge Temperature = 2.49°C
Time taken to begin discharge = 1 hour 4mins

With Insulation
Water Discharge Temperature = 2.03°C
Time taken to begin discharge = 4hour 3mins

Warning!
If the Inta Zero valves are insulated, then due care must be taken to ensure that all external pipework and fittings are fully and appropriately insulatedand sealed. Failure to do so could prevent the proper operation of the Zero valve resulting in colder areas of a system being damaged by freezing. The Anti-vacuum valve must be kept clear at all times, Intatec recommend using the ZEROGUARD anti-vacuum cover (inspected on annual service).

Pack Contents

2x Zero Anti-Freeze Valves

2x Zero Valve Insulation Jackets

2x Zero Guard Anti-Freeze Protectors

1x Tube of Condensate Pro Bond & Seal

Building Regulations Part L
R290 Refrigerant

Related Products